Commercial Helical Piles in Florida & Georgia

Micropile, Screw Piles, and Helical Piers in Florida and Georgia

Helical piles are a factory-manufactured steel foundation system consisting of a central shaft with one or more helix-shaped bearing plates, commonly referred to as blades or flights, welded to the lead section. Extension shafts, with or without additional helix blades, are used to extend the pile to competent load-bearing soils and to achieve design depth and capacity. Brackets are used at the tops of the piles for attachment to structures, either for new construction or retrofit applications. Helical piles are advanced (screwed) into the ground with the application of torque.

The terms helical piles, screw piles, helical piers, helical anchors, helix piers, and helix anchors are often used interchangeably by specifiers. However, the term ‘pier’ more often refers to a helical pile loaded in axial compression, while the term ‘anchor’ more often refers to a helical pile loaded in axial tension.

Get a FREE Quote!

Design Considerations

Helical piles are designed such that most of the axial capacity of the pile is generated through bearing of the helix blades against the soil. The helix blades are typically spaced three diameters apart along the pile shaft to prevent one blade from contributing significant stress to the bearing soil of the adjacent blade. Significant stress influence is limited to a ‘bulb’ of soil within about two helix diameters from the bearing surface in the axial direction and one helix diameter from the center of the pile shaft in the lateral direction. Each helix blade therefore acts independently in bearing along the pile shaft.

Multiple piles shall have a center to center spacing at the helix depth of at least four (4) times the diameter of the largest helix blade (ICC-ES AC358). The tops of the piles may be closer at the ground surface but installed at a batter away from each other in order to meet the spacing criteria at the helix depth. For tension applications, the uppermost helix blade shall be installed to a depth of at least twelve (12) diameters below the ground surface (ICC-ES AC358).

Determination of Capacity

The ultimate capacity of a helical pile may be calculated using the traditional bearing capacity equation:

Qu = ∑ [Ah (cNc + qNq)]

Where:
Qu = Ultimate Pile Capacity (lb)
Ah = Area of Individual Helix Plate (ft2)
c = Effective Soil Cohesion (lb/ft2)
Nc = Dimensionless Bearing Capacity Factor = 9
q = Effective Vertical Overburden Pressure (lb/ft2)
Nq = Dimensionless Bearing Capacity Factor

Total stress parameters should be used for short-term and transient load applications and effective stress parameters should be used for long-term, permanent load applications. A factor of safety of 2 is typically used to determine the allowable soil bearing capacity, especially if torque is monitored during the helical pile installation.

<p”>Like other deep foundation alternatives, there are many factors to be considered in designing a helical pile foundation. Groundworks recommends that helical pile design be completed by an experienced geotechnical engineer or other qualified professional.

Another well-documented and accepted method for estimating helical pile capacity is by correlation to installation torque. In simple terms, the torsional resistance generated during helical pile installation is a measure of soil shear strength and can be related to the bearing capacity of the pile.

Qu = KT

Where:

Qu = Ultimate Pile Capacity (lb)
K = Capacity to Torque Ratio (ft-1)
T = Installation Torque (ft-lb)

The capacity to torque ratio is not a constant and varies with soil conditions and the size of the pile shaft. Load testing using the proposed helical pile and helix blade configuration is the best way to determine project specific K-values. However, ICC-ES AC358 provides default K-values for varying pile shaft diameters, which may be used conservatively for most soil conditions. The default value for the Model 288 Helical Pile System (2 7/8-inch diameter) is K = 9 ft-1.

Get a FREE Quote!

Related Pages

Looking for a price? Get a no cost, no obligation free estimate.

Publish Date:

Last Modified Date:

Alpha Service Map

PROUDLY SERVING FLORIDA & GEORGIA

Fort Myers

1755 Benchmark Ave.
Fort Myers, FL 33905

Gainesville

309 NE 1st St.
Gainesville, FL 32601

Jacksonville

3115 Leon Rd.
Jacksonville, FL 32246

Miami

66 West Flagler St.
Ste. 949
Miami, FL 33130

Orlando

3723 Hogshead Rd
Apopka, FL 32703

Pensacola

89 W Hood Dr.
Pensacola, FL 32534

Pompano Beach

3200 W Copans Rd.
Pompano Beach, FL 33069

Sarasota

1680 Fruitville Rd.
Ste. 516
Sarasota, FL 34236

Tallahassee

66 Industrial Park Dr.
Monticello, FL 32344

Valdosta

100 N Patterson St.
Valdosta, GA 31601

West Palm Beach

515 N Flagler Dr.
Ste. P-300
West Palm Beach, FL 3340